Sonalert audible signal, medium continuous tone, operating current is 3mA at minimum voltage to 16mA at maximum voltage. Typical operating voltage is 1 volt minimum to 5 volts maximum DC, printed board mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous tone, operating current is 3mA at minimum voltage to 16mA at maximum voltage. Typical operating voltage is 4 volts minimum to 28 volts maximum DC, printed board mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous or fast pulse tone, operating current is 3mA at minimum voltage to 12mA at maximum voltage. Typical operating voltage is 6 volts minimum to 16 volts maximum DC, printed board mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous tone, operating current is 3mA at minimum voltage to 16mA at maximum voltage. Typical operating voltage is 1 volt minimum to 5 volts maximum DC, panel mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous tone, operating current is 6mA at minimum voltage to 21mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous tone, operating current is 6mA at minimum voltage to 21mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 1900 frequency +é-¦500Hz.
Sonalert audible signal, medium intermittent, slow pulse tone, operating current is 4mA at minimum voltage to 16mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 1900 frequency +é-¦500H
Sonalert audible signal, soft intermittent tone, slow pulse, operating current is 3mA at minimum voltage to 14mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, soft intermittent tone, fast pulse, operating current is 3mA at minimum voltage to 14mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 2900 frequency +é-¦500Hz.
Sonalert audible signal, medium continuous tone, operating current is 6mA at minimum voltage to 21mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 4500 frequency +é-¦500Hz.
Sonalert audible signal, medium intermittent, slow pulse tone, operating current is 4mA at minimum voltage to 16mA at maximum voltage. Typical operating voltage is 30 volts minimum to 120 volts maximum AC/DC non-polar, panel mount, 4500 frequency +é-¦500H